Axia V1050T Touch Screen

Category:

Description

Axia V1050T Touch ScreenFeatures

The Axia V1050T monitor is an intuitive touch screen patient monitor; patient information along with vital sign settings can be quickly modified to meet the needs of a patient s changing condition. Its upgradable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of: non-invasive blood pressure, motion tolerant SpO2, temperature and respiration rate.
The Axia V1050T monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.

  • High resolution 10.5 inch touch-screen display
  • Auto setting of alarm limits
  • Color-coded alarms
  • Graphical and tabular trends (72 hours)
  • Patient data entry
  • Battery backup (removable batteries)
  • Networking capability (wireless and non-wireless) • Color of the waveforms can be changed
  • Applications: Neonatal, pediatric and adult patients

Axia V1050T Touch Screen Specifications

Display

  • 10.5 inch color touch screen

Trace

  • 8 waveforms

Indicator

  • Alarm indicator
  • Power indicator
  • QRS beep and alarm sound

Trend Time

  • 1 – 72 hour
  • Recorder: Built-in, thermal array, 3 channels
  • Record width: 48mm
  • Recorder paper: 50mm
  • Record speed: 25mm/s, 50mm/s

Networking

  • Industry standard 802.11b/g wireless network

Power

  • Source: External AC power or internal battery
  • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery: Built-in & rechargeable lithium ion
  • Operating Time: 3+ hours

Environmental Specifications

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range: 30 ~ 300bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm

RESP

  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

Sp02

  • ASpO2: Anti-motion SpO2
  • SpO2% Range: • SpO2 Accuracy: 0-100%
  • Pulse Rate Range: ±2% (70 ~ 100%, non-motion), ±3% (70 ~ 100%, motion)
  • Pulse Rate Accuracy: ±2 bpm (non-motion, ±3 bpm (motion)
  • Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%
  • SpO2 Probe: Red light LED wavelength 660nm±5nm, Infrared light LED wavelength 940nm±10nm