Description
Axia V1050T Touch ScreenFeatures
The Axia V1050T monitor is an intuitive touch screen patient monitor; patient information along with vital sign settings can be quickly modified to meet the needs of a patient s changing condition. Its upgradable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of: non-invasive blood pressure, motion tolerant SpO2, temperature and respiration rate.
The Axia V1050T monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.
- High resolution 10.5 inch touch-screen display
- Auto setting of alarm limits
- Color-coded alarms
- Graphical and tabular trends (72 hours)
- Patient data entry
- Battery backup (removable batteries)
- Networking capability (wireless and non-wireless) • Color of the waveforms can be changed
- Applications: Neonatal, pediatric and adult patients
Axia V1050T Touch Screen Specifications
Display
- 10.5 inch color touch screen
Trace
- 8 waveforms
Indicator
- Alarm indicator
- Power indicator
- QRS beep and alarm sound
Trend Time
- 1 – 72 hour
- Recorder: Built-in, thermal array, 3 channels
- Record width: 48mm
- Recorder paper: 50mm
- Record speed: 25mm/s, 50mm/s
Networking
- Industry standard 802.11b/g wireless network
Power
- Source: External AC power or internal battery
- AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
- Battery: Built-in & rechargeable lithium ion
- Operating Time: 3+ hours
Environmental Specifications
- Input: 5-lead ECG cable and standard AAMI line for connection
- Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
- Gain Choice : x0.5, x1, x2, x4
- Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
- ECG Waveforms: 7 channels
- Penetration Voltage: 4000VAC 50/60Hz
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
- HR Display Range: 30 ~ 300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm
RESP
- Measure Method: RA-LL impedance
- Range: 0 ~ 120 rpm
- Accuracy: ±3 rpm
- Alarm Limit Setting: upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm
- Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
Sp02
- ASpO2: Anti-motion SpO2
- SpO2% Range: • SpO2 Accuracy: 0-100%
- Pulse Rate Range: ±2% (70 ~ 100%, non-motion), ±3% (70 ~ 100%, motion)
- Pulse Rate Accuracy: ±2 bpm (non-motion, ±3 bpm (motion)
- Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%
- SpO2 Probe: Red light LED wavelength 660nm±5nm, Infrared light LED wavelength 940nm±10nm