Axia V1200T Touch Screen

Category:

Description

Axia V1200T Touch ScreenFeatures

The Axia V1200T monitor is an intuitive touch screen patient monitor; patient information along with vital sign settings can be quickly modified to meet the needs of a patient’s changing condition. Its upgradable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of: non-invasive blood pressure, motion tolerant SpO2, temperature, respiration rate and capnography.
The Axia V1200T monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.

  • High resolution 12.1 inch touch-screen display
  • Capnography with EtCO2 monitoring (optional)
  • Auto setting of alarm limits
  • Color-coded alarms
  • Graphical and tabular trends (72 hours)
  • Patient data entry
  • OxiCRG, drug dose calculation
  • Trace: 8 wave forms
  • Trend Time: 1 – 72 Hours
  • Networking capability (wireless and non-wireless)
  • Color of the waveforms can be changed
  • Battery backup (removable batteries)
  • Weight: 8.45 lbs.
  • Applications: Neonatal, pediatric and adult patients

Axia V1200T Touch Screen Specifications

GENERAL SPECIFICATIONS

  • Display: 12.1 inch color touch screen
  • Trace: 8 waveforms
  • Indicator: Alarm indicator, Power indicator, QRS beep and alarm sound
  • Trend time: 1 – 72 hour, Recorder: Built-in, thermal array, 3 channels Record width: 48mm, Recorder paper: 50mm, Record speed: 25mm/s, 50mm/s

Networking

  • Industry standard 802.11b/g wireless network

Power

  • Source: External AC power or internal battery
  • AC Power: 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery: Built-in & rechargeable lithium ion
  • Operating Time: 3+ hours

Environmental Specifications

  • Temperature: Operating: 5 ~ 40 °C, Storage: -20 ~ 65 °C
  • humidity range: Operating: ≤80 % Storage: ≤80 %

ECG

  • Input: 5-lead ECG Cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range: 30 ~ 300bpm
  • Accuracy: ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting: upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm

RESP

  • Measure Method: RA-LL impedance
  • Range: 0 ~ 120 rpm
  • Accuracy: ±3 rpm
  • Alarm Limit Setting: upper limit 6 ~ 120 rpm, lower limit 3 ~ 120 rpm
  • Sweep Speed: 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

Sp02

  • ASpO2: Anti-motion SpO2
  • SpO2% Range: 0-100%
  • SpO2 Accuracy: ±2% (70 ~ 100%, non-motion), ±3% (70 ~ 100%, motion)
  • Pulse Rate Range: 30-250 bpm
  • Pulse Rate Accuracy: ±2 bpm (non-motion, ±3 bpm (motion)
  • Alarm Limit Setting: upper limit 70 ~ 100%, lower limit 70 ~ 100%
  • SpO2 Probe: Red light LED wavelength 660nm±5nm, Infrared light LED wavelength 940nm±10nm